Details
Working Principle
The fuel is burnt at firebox and the high temperature is produced. The quantity of heat will conduct to air to be heated through heat exchange device.Through heat exchange, the temperature of air is dropped to less than 250℃ and the air will be discharged. The air to be heated is sent to hot air furnace through distribution blow fan. After absorbed heat to the rated value, the air will be sent from the vent of hot air . When the temperature of hot air reaches the rated upper limit, the burner can stop or turn to small re automatically . When the temperature of hot air drops to the rated low limit, the burner can burn or turn to big re automatically .
Technical Parameter
Spec |
Combustion device spec |
oil combustion heat supply kg/h |
capacity104kcal/h |
overall dimensions L×W×Hmm |
jpt air opening L×Wmm |
total weight kg |
RLY1 |
RIELLO.G3/DL3FS |
1.3-1.6 |
1 |
1200×1200×1600 |
Φ200 |
460 |
RLY4 |
RIELLO.G10/DL10FS |
5-6.5 |
4 |
1700×1300×1600 |
Φ250 |
850 |
RLY10 |
RIELLO.G20/DL23FS |
13-16 |
10 |
2300×1568×1870 |
Φ300 |
2200 |
RLY20 |
RIELLO 1G/DL34FS |
26-32 |
20 |
2800×1568×1870 |
Φ400 |
2670 |
RLY30 |
RL50/DL55FT |
39-48 |
30 |
3400×1568×1870 |
Φ450 |
3060 |
RLY40 |
RL70/DL75FT |
52-64 |
40 |
4440×1768×2070 |
Φ550 |
5600 |
RLY60 |
RL100/DL100FT |
78-96 |
60 |
5140×1868×2070 |
Φ600 |
8460 |
RLY100 |
PRESS 4G/DL 120FT |
130-140 |
100 |
6440×2480×2300 |
550×600 |
12800 |
RLY160 |
P300/DL250FT |
200-270 |
160 |
7470×2920×3480 |
750×900 |
15780 |
RLY200 |
P300/DL300FT |
260-300 |
200 |
8175×2920×3480 |
750×900 |
18500 |
RLY360 |
G1510 |
480-620 |
360 |
9300×2920×3480 |
|
21000 |